N12, NC12 Controllers and Modbus

N12 Model

Nokian N Series

VAR Controller 12 Steps

Intelligent Power Factor Controllers are designed and manufactured to control automatic capacitor banks. They provide your network with efficient reactive power compensation, measuring and supervising communication features.

 

Specifications:  

4-Quadrant Generator Application

Input Current

5 A

Input Voltage

120 volts 10 VA

Insensitive to CT Polarity

Insensitive to Phase Rotation

Output

(6) N6 or N12 (12) SPST contact 5 A 120 V

   



NC12 Model

 

  • Brochure
  • Data Sheets & Drawings
  • Technical Specification
  • Design Guide
  • Instruction Manual
  • Accessories

 

Specifications:

4-Quadrant Generator Application

 

Certification

cCSAus, cULus

Color Casing

RAL 7016

Communication Module

NCWatch software (NC12)

Dimensions

144 x 144 x 75 mm

(5.7 x 5.7 x 3.0 in)

Input Current

5 A

Input Voltage

120 volts 10 VA

Insensitive to CT Polarity

 

Insensitive to Phase Rotation

 

Languages

English, French, Spanish, Finnish, Swedish, Deutch, German

Modbus Communication

(RS485) NC12

Mounting Type

Flush or DIN-Rail

Nema/Type

IP41, IP20/1 & 12

Output

(12) SPST contact 5 A 120 V

Output Terminals

Plug-in Type

Temperature (Inside Sensor) in Option the Remote Sensor

 

 



MCU Modbus Adapter

 

  • Brochure
  • Data Sheets & Drawings
  • Technical Specification
  • Design Guide
  • Instruction Manual
  • Accessories

 

Modbus is a serial, asynchronous protocol. The Modbus protocol does not specify the physical interface. The NC12-MCU Modbus adapter has an RS-485 interface with RS232 port for PC communication.

Modbus is designed to allow a communication between components of an installation including one or several supervision systems.

Amongst the countless advantages and benefits of a communication capability, Modbus is a well spread protocol in the industrial world and allow, for example, interconnection between components for linked actions and information centralisation.

Gateway between Modbus and other fieldbus can be found in the market giving access to several other fieldbus systems.

The Modbus adapter is an optional device for Nokian Capacitors Power Factor Controller NC12 which enables the connection of the NC12-MCU to a Modbus system. The NC12-MCU is considered as a slave unit in the Modbus network. With the MCU Modbus adapter, all NC12 information (measurements, serial number, alarm messages,..) and all parameters settings (switching strategy, protection levels,..) are accessible.